Calculate reportable Fannie Mae & MLS Above-Grade Heated GLA in exact feet and inches,
separate finished below-grade basement square footage from non-GLA garages/porches, and
verify sloped attic or bonus rooms against the 5-ft minimum / 50% >= 7-ft ceiling rule.
Total Finished (Above + Below)1,330 sq ftExcludes 32 sq ft sub-height sloped area
Room-by-Room Dimension Worksheet
Enter clear interior room dimensions in feet and inches, or enable the exterior wall
framing factor when estimating exterior-footprint GLA from interior laser measurements.
Length (ft / in)
ftin
Width (ft / in)
ftin
Qualified360 sf
Length (ft / in)
ftin
Width (ft / in)
ftin
Qualified203 sf
Length (ft / in)
ftin
Width (ft / in)
ftin
Qualified224 sf
Length (ft / in)
ftin
Width (ft / in)
ftin
Qualified184 sf
QUALIFIES: 184 sq ft above 5'-0" line
included
Length (ft / in)
ftin
Width (ft / in)
ftin
Qualified360 sf
Length (ft / in)
ftin
Width (ft / in)
ftin
Qualified420 sf
Need an Exact Exterior-Perimeter MLS Sheet + ANSI GLA Table?
Upload a field sketch or draw walls in PlanCaliber to compute exact exterior-perimeter
polygons automatically and export crisp white MLS floor plans, 3D dollhouses, and
1/4"=1'-0" vector PDFs.
ANSI Z765-2021 Square Footage Reference Guide for US Listings & Appraisals
Since April 2022, Fannie Mae requires residential appraisals on single-family dwellings to
follow the ANSI Z765-2021 measurement standard (measured to the nearest inch
or tenth of a foot). Key field rules every agent, homeowner, and remodeler should verify:
1. Exterior Perimeter vs. Interior Room Add-Up
ANSI Z765-2021 defines Gross Living Area by measuring the exterior face of above-grade finished walls (or adding 0.5 ft / 6 in to interior wall-to-wall measurements
for standard condo or inaccessible exterior runs). Simply summing clear interior room dimensions
omits interior partitions, closets, hallways, and exterior framing—typically under-reporting
total GLA by 6% to 12%.
2. Above-Grade vs. Below-Grade Basement Rule
If any portion of a level's floor is below exterior finished grade (including
daylight and walkout basements), ANSI Z765 classifies that entire level as below-grade area. Finished basement rooms still hold substantial market
value, but must be reported on a separate Below-Grade Finished line—never merged into
Above-Grade GLA.
3. Sloped Ceilings: 5-Ft Minimum & 50% at 7-Ft
In bonus rooms, Cape Cod upper floors, and finished attics with sloped rafters, floor
space with ceiling height under 5'-0" (60") is strictly excluded.
Furthermore, at least 50% of the remaining (>=5'-0") area in
that room must reach a ceiling height of 7'-0" (84") or higher
to count as finished square footage.
4. Stairways, Vaulted Foyers & Detached ADUs
Interior stairs count toward the level from which they descend (not exceeding the area
of the stair opening), while two-story open foyers and vaulted living room voids are
excluded on the upper floor. Detached backyard ADUs, guest cottages, and finished bonus
suites above detached garages must be itemized separately from the main dwelling's GLA.