Solve exact floor-to-floor total rise, optimal riser count, unit riser height, total
horizontal run, 2x12 stringer carriage length, and upper-floor stairwell opening length
for 6'-8" (80") clear headroom in architectural feet and inches.
Drop This Stairwell into a Scaled 2D & 3D Floor Plan
Place straight or L-turn stair assemblies in PlanCaliber, automatically stack aligned
2nd-story or basement structural shells, and export 1/4"=1'-0" vector PDF
blueprints and AutoCAD DXF sheets.
What is the maximum stair riser height and minimum tread depth in IRC R311.7?
Under IRC R311.7.5.1 and R311.7.5.2, residential
risers cannot exceed 7-3/4" (7.75") and tread depth must be at
least 10" measured horizontally from nosing to nosing. Dimensional
uniformity is strictly enforced: the tallest and shortest risers (or deepest and
shallowest treads) within any single flight cannot vary by more than 3/8".
How is the stairwell floor cutout opening calculated for 80" headroom?
IRC R311.7.2 measures minimum 6'-8" (80") headroom vertically from a sloped line connecting the tread nosings up to the finished
soffit of the stairwell header. Because the stair must clear both the upper floor
assembly thickness and 80" of vertical height, minimum finished opening equals ((80" + Floor Assembly) / Unit Rise) × Tread Run.
What is the minimum clear stairway width and landing size?
IRC R311.7.1 and R311.7.6 require at least 36" clear width above handrail height and a floor or landing at the
top and bottom of every exterior and interior flight measuring at least as wide as the
stair and at least 36" in the direction of travel.
How many 2x12 stringers should support a 36" to 48" residential stair?
Standard 1" nominal hardwood or 5/4" framing treads typically span 16" on
center—requiring 3 stringers for a 36" stair and 4 stringers for 42"–48" stairs, maintaining at least 5"