IRC R311.7 Stair Rise, Run, Stringer & Cutout Calculator

Solve exact floor-to-floor total rise, optimal riser count, unit riser height, total horizontal run, 2x12 stringer carriage length, and upper-floor stairwell opening length for 6'-8" (80") clear headroom in architectural feet and inches.

Unit Riser × Optimal Count IRC PASS
16 @ 7 1/2" 7.54" exact • IRC R311.7.5.1 max 7-3/4"
Total Floor-to-Floor Rise 10'-0 5/8" 120.63" (9'-0" ceil + 12 5/8" floor)
Total Horizontal Run (15 Treads) 12'-9 3/4" 153.75" @ 10 1/4" tread • 36.3° pitch
Min Floor Cutout & Stringer 10'-5 7/8" Stringer: 16'-3 3/8" (18' stock)

Floor-to-Floor & Framing Inputs

IRC R311.7
Finished Lower Ceiling Height (ft / in)
ft in
IRC R311.7.5.2 min: 10.0"
IRC R311.7.1 min: 36"
IRC R311.7.2 min: 80" (6'-8")
Riser Count Selection
16 risers
Auto optimal <= 7.75"
IRC R311.7 COMPLIANCE SCHEDULE
Unit Riser Height (7.54" <= 7.75") PASS
Unit Tread Depth (10.25" >= 10.00") PASS
Clear Stair Width (36" >= 36") PASS
Headroom Clearance (80" >= 80") PASS

Scaled Architectural Stair Section & Cutout Diagram

True-proportion 1:1 vertical/horizontal section showing 16 risers, 15 treads, 12 5/8" floor assembly, and 80" vertical headroom plane.

SECT A-A • SCALE AUTO
6'-8" HEADROOMCUTOUT: 10'-5 7/8"TOTAL RUN: 12'-9 3/4" (15 TREADS)TOTAL RISE: 10'-0 5/8"FLOOR ASSY: 12 5/8"
ROUGH FRAMING CUTOUT (+1.5" TRIMMER) 10'-7 3/8" × 3'-3 1/2"
2x12 STRINGER CARRIAGE LENGTH 16'-3 3/8" (4 stringers @ 16" OC)
UNIT STEP CALLOUT 16 Risers @ 7 1/2" • 15 Treads @ 10 1/4"

Drop This Stairwell into a Scaled 2D & 3D Floor Plan

Place straight or L-turn stair assemblies in PlanCaliber, automatically stack aligned 2nd-story or basement structural shells, and export 1/4"=1'-0" vector PDF blueprints and AutoCAD DXF sheets.

IRC Section R311.7 Residential Stairway Code Reference & FAQ

What is the maximum stair riser height and minimum tread depth in IRC R311.7?

Under IRC R311.7.5.1 and R311.7.5.2, residential risers cannot exceed 7-3/4" (7.75") and tread depth must be at least 10" measured horizontally from nosing to nosing. Dimensional uniformity is strictly enforced: the tallest and shortest risers (or deepest and shallowest treads) within any single flight cannot vary by more than 3/8".

How is the stairwell floor cutout opening calculated for 80" headroom?

IRC R311.7.2 measures minimum 6'-8" (80") headroom vertically from a sloped line connecting the tread nosings up to the finished soffit of the stairwell header. Because the stair must clear both the upper floor assembly thickness and 80" of vertical height, minimum finished opening equals ((80" + Floor Assembly) / Unit Rise) × Tread Run.

What is the minimum clear stairway width and landing size?

IRC R311.7.1 and R311.7.6 require at least 36" clear width above handrail height and a floor or landing at the top and bottom of every exterior and interior flight measuring at least as wide as the stair and at least 36" in the direction of travel.

How many 2x12 stringers should support a 36" to 48" residential stair?

Standard 1" nominal hardwood or 5/4" framing treads typically span 16" on center—requiring 3 stringers for a 36" stair and 4 stringers for 42"–48" stairs, maintaining at least 5" effective uncut throat depth (or engineered LVL stringers for long basement spans).