Wall, Attic & Basement Insulation R-Value Calculator

Size US residential thermal envelopes against IECC / IRC Table N1102.1.3 climate-zone targets: calculate 2x4 (R-13/R-15) and 2x6 (R-19/R-21) batt bags with stud framing deductions and optional 1" XPS R-5 continuous sheathing, attic blown-in cellulose or fiberglass bags with existing-R subtraction and settled depth, or basement 4'x8' rigid foam sheets, adhesive tubes, and seam tape.

BLOWN-IN BAGS (+10%) 67 bags 25-lb Cellulose (+R-38 add-on)
IECC ZONES 4-5 TARGET R-49 MEETS TARGET (R-49)
ADDED SETTLED DEPTH 10.9" 14.6" total depth (3.5 R/in)
EST. EAVE BAFFLES 47 chutes 1,500 sq ft attic (verify rafter bays)

Envelope Geometry & Insulation Spec

IECC / IRC N1102.1.3
Assembly Mode
US IECC Climate Zone
Blown-In Material
Target Attic R-Value
Existing Attic Insulation (Subtracted)
Attic Floor Area 1,500 sq ft
Add-On R-Value Required +R-38 (R-49 minus R-11)
Blown-In Bags (+10%) 67 bags (950 R-sf/bag)
Settled Depth (Added / Total) 10.9" added / 14.6" total
Est. Eave Ventilation Baffles 47 chutes (verify rafter bays)

Live Thermal Envelope Section

SHEET A-501
SHEET A-501 · THERMAL ENVELOPE & R-VALUE SECTIONMEETS ZONE TARGETATTIC BLOWN-IN CELLULOSE SECTION · +10.9" ADDED (14.6" TOTAL)EAVE BAFFLE CHUTE(47 EST. BAYS)NEW CELLULOSE: +R-38 (10.9")EXISTING R-11 (~3.7")AIR-SEALED CEILING DRYWALL & TOP PLATES0"6"12"18"24"14.6"DEPTH RULERORDER: 67 CELLULOSE BAGS · +10.9" DEPTH · 47 EAVE BAFFLES · R-49

IECC Envelope, Air-Sealing & Vapor-Control Advisories

  • Adding +R-38 of cellulose (~10.9" settled depth) over existing R-11 brings the attic to R-49, meeting Zones 4-5 (R-49).
  • Air-seal all top plates, recessed lights (ICAT-rated), bath fan housings, and chase openings with fire-rated foam BEFORE blowing insulation, and install 47 estimated eave baffles (verify exact rafter bay count) to keep soffit vents open.
  • Staple cardboard depth rulers every 300 sq ft across the attic trusses and verify the bag-coverage chart printed on the exact manufacturer bag you purchase.
Draft Full Scaled Floor Plans & Framing Takeoffs in 2D/3D Studio

Draw your ADU, basement suite, garage, or remodel free ($0) with watermarked proof PNGs. Export clean unwatermarked Vector PDF from $9 one-time, or full 5-sheet Vector PDF + AutoCAD R12 .DXF + Material Takeoff .CSV for $19.

US IECC / IRC Table N1102.1.3 R-Value Reference (Climate Zones 1-8)

IECC Climate ZoneRepresentative US CitiesAttic / CeilingWood-Framed WallBasement WallField Envelope Notes
Zones 1-2 (Hot-Humid / South)Miami, Houston, Phoenix, Orlando, New OrleansR-30 (Z1) / R-49 (Z2)R-13 cavityR-0 (R-5 conditioned)Prioritize radiant barrier/attic R-value and avoid interior poly vapor barriers in cooling climates.
Zone 3 (Warm / Southeast & SW)Atlanta, Dallas, Charlotte, Los Angeles, Las VegasR-38R-20 or R-13+5ciR-5 continuous2x6 R-21 batts or 2x4 R-13 + 1" XPS continuous sheathing both satisfy the IRC wall table.
Zones 4-5 (Mixed & Cool)Seattle, Denver, Chicago, Boston, Philadelphia, NashvilleR-49R-20 or R-13+5ciR-10 continuousMost common US residential envelope tier: R-49 attic blown-in, 2x6 R-21 walls, and 2" XPS R-10 basement walls.
Zones 6-8 (Cold & Very Cold)Minneapolis, Milwaukee, Burlington, Bozeman, AnchorageR-60R-20+5ci (R-25+)R-15 continuousContinuous exterior foam (1" XPS R-5ci) over 2x6 R-21 walls stops stud thermal bridging and frost condensation.

Wall Batt, Blown-In Attic & Basement Insulation FAQ

What R-value do I need for my attic, walls, and basement under the IECC / IRC?

Under IRC Table N1102.1.3 (IECC residential envelope table), Climate Zones 1-2 typically require R-30 to R-49 in attics and R-13 in wood-framed walls. Climate Zone 3 targets R-38 attics, R-20 (or R-13+5ci) walls, and R-5 basement walls. Climate Zones 4-5 target R-49 attics, R-20 (or R-13+5ci) walls, and R-10 continuous basement insulation. Cold Climate Zones 6-8 target R-60 attics, R-20+5ci walls, and R-15 continuous basement walls. Always verify your local county or state energy-code adoption before ordering.

How many bags of blown-in cellulose or fiberglass do I need for R-49 in a 1,500 sq ft attic?

For a bare 1,500 sq ft attic (R-0 existing) targeting R-49, blown-in cellulose (~3.5 R/in, ~950 R-sf per 25-lb bag) requires about 78 net bags (~86 bags with 10% waste) at roughly 14 inches settled depth. If you already have R-11 (~3.5 inches) in the attic, you only need to add +R-38 (~10.9 inches), which drops the order to about 66 bags including 10% waste. Blown fiberglass (~2.5 R/in, ~1,150 R-sf per 29-lb bag) uses fewer bags (~55 bags for +R-38) but requires greater depth (~15.2 inches).

Why does the wall calculator deduct 10% for 16" OC studs and 7% for 24" OC studs?

Batt insulation only fills the open wood framing cavities, not the lumber itself. On a standard 16" OC framed wall, studs, double top plates, bottom plates, and window/door headers occupy roughly 10% of the net wall area (and about 7% on 24" OC framing). Deducting the framing factor prevents over-buying bags while still letting you add a clean 10% cut-and-fit allowance.

Should I use 2x4 R-15 or 2x6 R-21 batts, and when do I need continuous exterior foam?

A 2x4 stud cavity (3.5 inches deep) holds R-13 standard or R-15 high-density batts, which meets Climate Zones 1-2 on its own. In Zones 3-5, IRC Table N1102.1.3 requires either 2x6 walls with R-20/R-21 cavity batts OR 2x4 R-13/R-15 batts paired with 1-inch continuous exterior XPS foam (R-5ci). In Climate Zones 6-8, combining 2x6 R-21 batts with 1-inch continuous exterior foam (R-26 nominal) stops heat loss through the wood studs.

Why should basement concrete walls use continuous rigid foam (XPS/Polyiso) instead of fiberglass batts against concrete?

Fiberglass batts placed directly against cool below-grade concrete allow warm, humid indoor air to pass through and condense on the concrete surface, causing mold and damp framing. Gluing continuous 4x8 XPS or Polyiso rigid foam sheets directly to the foundation wall with foam-compatible adhesive and taping every seam creates both a thermal break and an airtight vapor retarder. Remember IRC R316.4 requires covering rigid foam with at least 1/2-inch gypsum drywall as a thermal ignition barrier in habitable spaces.

Preliminary Energy-Estimating & Local Code-Verification Notice: This calculator provides preliminary insulation material takeoffs and IECC / IRC Table N1102.1.3 reference targets for planning and budgeting. Actual bag coverage varies by manufacturer density, blown-in machine hopper settings, joist spacing, and framing layout. Vapor-retarder class (Class I/II/III), fire-blocking, ICAT recessed-light clearances, and IRC R316.4 foam thermal-barrier rules vary by state and municipal energy code. Verify local building department requirements and manufacturer bag coverage charts before purchasing or installing materials.