Garage-Conversion Studio ADU

420 sq ft 2-car garage conversion studio with full kitchen & bath

TPL-07 • PC-2026-107 ADU & Basement Studio / 1 Bath Ceiling 9'-0"
SHEET A-201 • ARCHITECTURAL FLOOR PLAN PREVIEW OVERALL 24'-0" x 17'-6"
Garage-Conversion Studio ADU scaled architectural floor plan showing walls, door swings, glazing, and room dimensions

Room Schedule (4 Enclosed Zones)

INSET CLEAR INTERIOR DIMENSIONS
Room NameClear Interior SpanClear Area (sq ft)Floor FinishGLA Status
Kitchenette15'-3" x 6'-7"101 sq ftLuxury Vinyl PlankHeated GLA
Bathroom7'-3" x 9'-9"71 sq ftPorcelain TileHeated GLA
Walk-In Closet7'-3" x 6'-3"46 sq ftLuxury Vinyl PlankHeated GLA
Studio Living / Sleep15'-3" x 9'-5"144 sq ftLuxury Vinyl PlankHeated GLA

Doors & Cased Openings (4)

Opening TypeClear WidthQty
Single Hinged Door
80" head height, clear swing arc
3'-0" (36")1
Cased Archway Opening
Trimmed pass-through (verify header)
8'-0" (96")1
Single Hinged Door
80" head height, clear swing arc
2'-4" (28")1
Recessed Pocket Door
Zero swing-arc wall pocket
2'-6" (30")1

Windows & Egress Glazing (3)

Glazing TypeRough WidthQty
Standard Architectural Window
Double-pane insulated glazing
3'-6" (42")1
IRC R310 Egress Window
Min 5.7 sq ft net clear opening, <=44" sill
4'-0" (48")1
Standard Architectural Window
Double-pane insulated glazing
2'-2" (26")1

Kitchen, Bath & Architectural Fixtures (9)

MarkFixture / Cabinet DescriptionPlan FootprintQty
REF-2828" Fridge28" W x 26" D1
SB3030" Sink Base30" W x 24" D1
RNG-2424" Studio Range24" W x 24" D1
B3030" Base Cabinet30" W x 24" D1
BED-Q1Studio Murphy/Queen Bed60" W x 80" D1
SHW-4848"x34" Walk-In Shower48" W x 34" D1
WC-1Studio WC20" W x 27" D1
VAN-3030" Bath Vanity30" W x 20" D1
WD-24Combo Washer/Dryer24" W x 25" D1

IRC / NKBA Space-Planning Notes & Scope Disclaimer

  • Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
  • IRC R310 Emergency Escape & R311 Circulation: Sleeping rooms incorporate egress glazing sized for >=5.7 sq ft net clear opening (5.0 sq ft at grade-floor openings) with sill height <=44" above finished floor, alongside >=36" clear hallway width.
  • NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is preliminary space-planning and CAD drafting software, not a licensed architectural or structural engineering firm. All templates, takeoff quantities, and exported sheets are for design planning, estimating, and contractor coordination. Verify all site dimensions, soil and structural load paths, header sizing, egress openings, and local building code amendments with a licensed professional and your local building department prior to construction.