40x60 Barndominium & Shop-House
3-Bed / 2-Bath post-frame home with 24'x40' drive-through shop & 1,440 sq ft heated living quarters
Room Schedule (9 Enclosed Zones)
| Room Name | Clear Interior Span | Clear Area (sq ft) | Floor Finish | GLA Status |
|---|---|---|---|---|
| Drive-Thru Shop | 23'-2" x 38'-11" | 902 sq ft | Polished Concrete | Non-GLA / Auxiliary |
| Utility & Mudroom | 9'-7" x 9'-3" | 88 sq ft | Porcelain Tile | Heated GLA |
| Bedroom 3 | 10'-8" x 9'-3" | 99 sq ft | Cut-Pile Carpet | Heated GLA |
| Primary Bedroom | 14'-3" x 14'-3" | 204 sq ft | Cut-Pile Carpet | Heated GLA |
| Primary Bath | 14'-3" x 7'-8" | 109 sq ft | Porcelain Tile | Heated GLA |
| Hall Bath | 10'-3" x 6'-8" | 68 sq ft | Porcelain Tile | Heated GLA |
| Bedroom 2 | 14'-3" x 9'-3" | 132 sq ft | Cut-Pile Carpet | Heated GLA |
| Great Room & Kitchen | 20'-7" x 29'-3" | 601 sq ft | White Oak Hardwood | Heated GLA |
| Hallway | 3'-8" x 6'-8" | 24 sq ft | White Oak Hardwood | Heated GLA |
Doors & Cased Openings (12)
| Opening Type | Clear Width | Qty |
|---|---|---|
Cased Archway Opening Trimmed pass-through (verify header) | 16'-0" (192") | 1 |
Cased Archway Opening Trimmed pass-through (verify header) | 12'-0" (144") | 1 |
Single Hinged Door 80" head height, clear swing arc | 3'-0" (36") | 3 |
Single Hinged Door 80" head height, clear swing arc | 2'-10" (34") | 2 |
Single Hinged Door 80" head height, clear swing arc | 2'-8" (32") | 2 |
Recessed Pocket Door Zero swing-arc wall pocket | 2'-6" (30") | 1 |
Cased Archway Opening Trimmed pass-through (verify header) | 3'-4" (40") | 1 |
Single Hinged Door 80" head height, clear swing arc | 2'-6" (30") | 1 |
Windows & Egress Glazing (12)
| Glazing Type | Rough Width | Qty |
|---|---|---|
Standard Architectural Window Double-pane insulated glazing | 4'-0" (48") | 5 |
Standard Architectural Window Double-pane insulated glazing | 3'-0" (36") | 3 |
IRC R310 Egress Window Min 5.7 sq ft net clear opening, <=44" sill | 4'-0" (48") | 3 |
Standard Architectural Window Double-pane insulated glazing | 2'-6" (30") | 1 |
Kitchen, Bath & Architectural Fixtures (21)
| Mark | Fixture / Cabinet Description | Plan Footprint | Qty |
|---|---|---|---|
| WD-54 | Side-by-Side Laundry | 54" W x 28" D | 1 |
| WH-50 | 50-Gal Water Heater | 24" W x 24" D | 1 |
| LKR-48 | Mudroom Locker Bench | 20" W x 48" D | 1 |
| REF-36 | 36" Refrigerator | 28" W x 36" D | 1 |
| B30 | 30" Base Cabinet | 24" W x 30" D | 1 |
| SB36 | 36" Sink Base | 24" W x 36" D | 1 |
| DW-24 | 24" Dishwasher | 24" W x 24" D | 1 |
| RNG-30 | 30" Range | 26" W x 30" D | 1 |
| ISL-36x96 | 36"x96" Barndo Island | 36" W x 96" D | 1 |
| DIN-72 | 72" Farmhouse Table | 42" W x 72" D | 1 |
| SOFA-84 | 84" Great Room Sofa | 84" W x 36" D | 1 |
| BED-K1 | Primary King Bed | 76" W x 80" D | 1 |
| BED-Q2 | Bedroom 2 Queen Bed | 60" W x 80" D | 1 |
| BED-Q3 | Bedroom 3 Queen Bed | 60" W x 80" D | 1 |
| VAN-60 | 60" Dual Primary Vanity | 21" W x 60" D | 1 |
| WC-1 | Primary WC | 20" W x 27" D | 1 |
| SHW-48 | 48"x36" Walk-In Shower | 48" W x 36" D | 1 |
| TUB-60 | 60" Soaking Tub | 60" W x 30" D | 1 |
| TUB-60B | 60" Hall Tub | 60" W x 30" D | 1 |
| WC-2 | Hall WC | 20" W x 27" D | 1 |
| VAN-42 | 42" Hall Vanity | 42" W x 21" D | 1 |
IRC / NKBA Space-Planning Notes & Scope Disclaimer
- Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 10'-0" ceiling plate height.
- ANSI Z765-2021 GLA Separation: Heated above-grade living area is calculated distinctly from unheated garages, mechanical/utility rooms, and detached structures so MLS sheets and preliminary appraisals stay transparent.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is
preliminary space-planning and CAD drafting software, not a licensed architectural or
structural engineering firm. All templates, takeoff quantities, and exported sheets are for
design planning, estimating, and contractor coordination. Verify all site dimensions, soil
and structural load paths, header sizing, egress openings, and local building code
amendments with a licensed professional and your local building department prior to
construction.