40x80 Barndominium w/ 3-Bed & RV Shop
3-Bed / 2-Bath post-frame residence with 30'x40' RV & equipment shop and 2,000 sq ft heated living
Room Schedule (11 Enclosed Zones)
| Room Name | Clear Interior Span | Clear Area (sq ft) | Floor Finish | GLA Status |
|---|---|---|---|---|
| Primary Bedroom | 15'-3" x 15'-3" | 233 sq ft | Cut-Pile Carpet | Heated GLA |
| Great Room & Kitchen | 20'-8" x 38'-11" | 803 sq ft | White Oak Hardwood | Heated GLA |
| Mudroom & Laundry | 12'-7" x 10'-3" | 129 sq ft | Porcelain Tile | Heated GLA |
| RV & Equipment Shop | 29'-2" x 38'-11" | 1,136 sq ft | Polished Concrete | Non-GLA / Auxiliary |
| Bedroom 3 | 12'-7" x 13'-3" | 166 sq ft | Cut-Pile Carpet | Heated GLA |
| Bedroom 2 | 15'-3" x 14'-3" | 218 sq ft | Cut-Pile Carpet | Heated GLA |
| Primary Bath | 8'-9" x 8'-8" | 76 sq ft | Porcelain Tile | Heated GLA |
| Walk-In Pantry | 12'-7" x 6'-8" | 83 sq ft | White Oak Hardwood | Heated GLA |
| Hall Bath | 8'-7" x 7'-8" | 65 sq ft | Porcelain Tile | Heated GLA |
| Walk-In Closet | 6'-2" x 8'-8" | 53 sq ft | Cut-Pile Carpet | Heated GLA |
| Hallway | 3'-8" x 7'-8" | 28 sq ft | White Oak Hardwood | Heated GLA |
Doors & Cased Openings (15)
| Opening Type | Clear Width | Qty |
|---|---|---|
Overhead Garage / Shop Door Sectional roll-up overhead track | 12'-0" (144") | 2 |
Single Hinged Door 80" head height, clear swing arc | 3'-0" (36") | 4 |
Single Hinged Door 80" head height, clear swing arc | 2'-6" (30") | 2 |
Cased Archway Opening Trimmed pass-through (verify header) | 3'-4" (40") | 1 |
Single Hinged Door 80" head height, clear swing arc | 2'-8" (32") | 2 |
Single Hinged Door 80" head height, clear swing arc | 2'-10" (34") | 1 |
Recessed Pocket Door Zero swing-arc wall pocket | 2'-6" (30") | 2 |
Sliding Glass / Patio Door Tempered safety glazing | 6'-0" (72") | 1 |
Windows & Egress Glazing (12)
| Glazing Type | Rough Width | Qty |
|---|---|---|
IRC R310 Egress Window Min 5.7 sq ft net clear opening, <=44" sill | 4'-0" (48") | 3 |
Standard Architectural Window Double-pane insulated glazing | 4'-0" (48") | 6 |
Standard Architectural Window Double-pane insulated glazing | 3'-0" (36") | 3 |
Kitchen, Bath & Architectural Fixtures (20)
| Mark | Fixture / Cabinet Description | Plan Footprint | Qty |
|---|---|---|---|
| REF-36 | 36" Refrigerator | 28" W x 36" D | 1 |
| B30 | 30" Base Cabinet | 24" W x 30" D | 1 |
| SB36 | 36" Sink Base | 24" W x 36" D | 1 |
| DW-24 | 24" Dishwasher | 24" W x 24" D | 1 |
| RNG-30 | 30" Range | 26" W x 30" D | 1 |
| ISL-36x96 | 36"x96" Barndo Island | 36" W x 96" D | 1 |
| DIN-72 | 72" Dining Table | 42" W x 72" D | 1 |
| SOFA-84 | 84" Great Room Sofa | 84" W x 36" D | 1 |
| BED-K1 | Primary King Bed | 76" W x 80" D | 1 |
| BED-Q2 | Bedroom 2 Queen Bed | 60" W x 80" D | 1 |
| BED-Q3 | Bedroom 3 Queen Bed | 60" W x 80" D | 1 |
| VAN-60 | 60" Dual Primary Vanity | 60" W x 21" D | 1 |
| WC-1 | Primary WC | 20" W x 27" D | 1 |
| SHW-48 | 48"x36" Walk-In Shower | 48" W x 36" D | 1 |
| TUB-60 | 60" Hall Tub | 60" W x 30" D | 1 |
| WC-2 | Hall WC | 20" W x 27" D | 1 |
| VAN-42 | 42" Hall Vanity | 42" W x 21" D | 1 |
| WD-54 | Side-by-Side Laundry | 54" W x 28" D | 1 |
| WH-50 | 50-Gal Water Heater | 24" W x 24" D | 1 |
| PNT-48 | Pantry Shelving Unit | 20" W x 48" D | 1 |
IRC / NKBA Space-Planning Notes & Scope Disclaimer
- Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 12'-0" ceiling plate height.
- ANSI Z765-2021 GLA Separation: Heated above-grade living area is calculated distinctly from unheated garages, mechanical/utility rooms, and detached structures so MLS sheets and preliminary appraisals stay transparent.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is
preliminary space-planning and CAD drafting software, not a licensed architectural or
structural engineering firm. All templates, takeoff quantities, and exported sheets are for
design planning, estimating, and contractor coordination. Verify all site dimensions, soil
and structural load paths, header sizing, egress openings, and local building code
amendments with a licensed professional and your local building department prior to
construction.