Side-by-Side 2-Unit Duplex

2,400 sq ft symmetric 2-unit duplex split by an 8" fire-rated demising wall, two 2-Bed / 1-Bath mirrored units

TPL-19 • PC-2026-119 Remodel & Whole Home 4 Bed / 2 Bath Ceiling 9'-0"
SHEET A-201 • ARCHITECTURAL FLOOR PLAN PREVIEW OVERALL 60'-0" x 40'-0"
Side-by-Side 2-Unit Duplex scaled architectural floor plan showing walls, door swings, glazing, and room dimensions

Room Schedule (12 Enclosed Zones)

INSET CLEAR INTERIOR DIMENSIONS
Room NameClear Interior SpanClear Area (sq ft)Floor FinishGLA Status
Unit A Bedroom 112'-3" x 12'-3"151 sq ftCut-Pile CarpetHeated GLA
Unit A Living & Kitchen16'-6" x 38'-11"641 sq ftWhite Oak HardwoodHeated GLA
Unit B Living & Kitchen16'-6" x 38'-11"641 sq ftWhite Oak HardwoodHeated GLA
Unit B Bedroom 112'-3" x 12'-3"151 sq ftCut-Pile CarpetHeated GLA
Unit B Full Bath8'-3" x 7'-8"63 sq ftPorcelain TileHeated GLA
Unit B Laundry8'-3" x 5'-8"47 sq ftPorcelain TileHeated GLA
Unit B Bedroom 212'-3" x 12'-3"151 sq ftCut-Pile CarpetHeated GLA
Unit A Bedroom 212'-3" x 12'-3"151 sq ftCut-Pile CarpetHeated GLA
Unit A Laundry8'-3" x 5'-8"47 sq ftPorcelain TileHeated GLA
Unit A Full Bath8'-3" x 7'-8"63 sq ftPorcelain TileHeated GLA
Unit A Hallway3'-8" x 13'-8"49 sq ftWhite Oak HardwoodHeated GLA
Unit B Hallway3'-8" x 13'-8"49 sq ftWhite Oak HardwoodHeated GLA

Doors & Cased Openings (14)

Opening TypeClear WidthQty
Single Hinged Door
80" head height, clear swing arc
3'-0" (36")4
Cased Archway Opening
Trimmed pass-through (verify header)
3'-4" (40")2
Single Hinged Door
80" head height, clear swing arc
2'-8" (32")4
Single Hinged Door
80" head height, clear swing arc
2'-6" (30")2
Closet Bifold Door
Wardrobe / laundry access
2'-8" (32")2

Windows & Egress Glazing (14)

Glazing TypeRough WidthQty
IRC R310 Egress Window
Min 5.7 sq ft net clear opening, <=44" sill
4'-0" (48")4
Standard Architectural Window
Double-pane insulated glazing
3'-0" (36")4
Standard Architectural Window
Double-pane insulated glazing
2'-6" (30")2
Standard Architectural Window
Double-pane insulated glazing
4'-0" (48")4

Kitchen, Bath & Architectural Fixtures (28)

MarkFixture / Cabinet DescriptionPlan FootprintQty
REF-AUnit A 36" Refrigerator28" W x 36" D1
SB36-AUnit A 36" Sink Base24" W x 36" D1
DW-AUnit A 24" Dishwasher24" W x 24" D1
RNG-AUnit A 30" Range26" W x 30" D1
ISL-AUnit A 36"x72" Island36" W x 72" D1
DIN-AUnit A Dining Table72" W x 42" D1
SOFA-AUnit A Living Sofa84" W x 36" D1
BED-A1Unit A Bed 1 Queen60" W x 80" D1
BED-A2Unit A Bed 2 Queen60" W x 80" D1
TUB-AUnit A 60" Tub60" W x 30" D1
WC-AUnit A WC20" W x 27" D1
VAN-AUnit A 42" Vanity42" W x 21" D1
WD-AUnit A Laundry54" W x 28" D1
WH-AUnit A Water Heater24" W x 24" D1
REF-BUnit B 36" Refrigerator28" W x 36" D1
SB36-BUnit B 36" Sink Base24" W x 36" D1
DW-BUnit B 24" Dishwasher24" W x 24" D1
RNG-BUnit B 30" Range26" W x 30" D1
ISL-BUnit B 36"x72" Island36" W x 72" D1
DIN-BUnit B Dining Table72" W x 42" D1
SOFA-BUnit B Living Sofa84" W x 36" D1
BED-B1Unit B Bed 1 Queen60" W x 80" D1
BED-B2Unit B Bed 2 Queen60" W x 80" D1
TUB-BUnit B 60" Tub60" W x 30" D1
WC-BUnit B WC20" W x 27" D1
VAN-BUnit B 42" Vanity42" W x 21" D1
WD-BUnit B Laundry54" W x 28" D1
WH-BUnit B Water Heater24" W x 24" D1

IRC / NKBA Space-Planning Notes & Scope Disclaimer

  • Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
  • NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is preliminary space-planning and CAD drafting software, not a licensed architectural or structural engineering firm. All templates, takeoff quantities, and exported sheets are for design planning, estimating, and contractor coordination. Verify all site dimensions, soil and structural load paths, header sizing, egress openings, and local building code amendments with a licensed professional and your local building department prior to construction.