24x24 2-Car Detached Garage & Workbench (576 Sq Ft)

576 sq ft clear-span 2-car detached garage with 16'-0" overhead sectional door, 12' rear workbench, 36" side man-door & 240V EV stub-out

TPL-36 • PC-2026-136 MLS & Commercial 2-Car Garage • 576 sq ft Ceiling 10'-0"
SHEET A-201 • ARCHITECTURAL FLOOR PLAN PREVIEW OVERALL 24'-0" x 24'-0"
24x24 2-Car Detached Garage & Workbench (576 Sq Ft) scaled architectural floor plan showing walls, door swings, glazing, and room dimensions

Room Schedule (1 Enclosed Zones)

INSET CLEAR INTERIOR DIMENSIONS
Room NameClear Interior SpanClear Area (sq ft)Floor FinishGLA Status
2-Car Garage & Workbench22'-11" x 22'-11"525 sq ftPolished ConcreteNon-GLA / Auxiliary

Doors & Cased Openings (2)

Opening TypeClear WidthQty
Overhead Garage / Shop Door
Sectional roll-up overhead track
16'-0" (192")1
Single Hinged Door
80" head height, clear swing arc
3'-0" (36")1

Windows & Egress Glazing (2)

Glazing TypeRough WidthQty
Standard Architectural Window
Double-pane insulated glazing
4'-0" (48")2

Kitchen, Bath & Architectural Fixtures (5)

MarkFixture / Cabinet DescriptionPlan FootprintQty
CAB-3636" Tool Storage Cabinet36" W x 24" D1
WB-48A48" Garage Workbench48" W x 24" D1
WB-48B48" Garage Workbench48" W x 24" D1
WB-48C48" Tool & Pegboard Bench48" W x 24" D1
CMP-26Air Compressor & Subpanel26" W x 26" D1

Inspect Real CAD Output Before You Pay

Download our unlocked 34x25 reference ADU specimen files to verify 1/4"=1'-0" vector PDF crispness, 8-layer AutoCAD R12 .DXF fidelity, clean MLS .SVG, and framing takeoff .CSV in your own viewer.

$0 Free Draft

Full 2D/3D studio + 1400x1050 watermarked Proof PNG & free 2D/3D share link.

$9 Print Pass (One-Time)

Unwatermarked 2-sheet vector PDF (A-101 + M-101), 2400px PNG, .SVG, unbranded share link & permanent re-edits.

$19 Full CAD Pack (One-Time)

5-sheet 1/4"=1'-0" PDF + 8-layer AutoCAD R12 .DXF + 3D .OBJ + Takeoff .CSV & permanent re-edits (14-day instant refund).

IRC / NKBA Space-Planning Notes & Scope Disclaimer

  • Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 10'-0" ceiling plate height.
  • 2-Car Bay Clearances & Rear Workbench: Exact 24'-0" x 24'-0" (576 sq ft Non-GLA) footprint pairs a centered 16'-0" sectional overhead door with 4'-0" flanking jamb piers, a 10'-0" ceiling height, a 12'-0" x 24" north workbench and tool cabinet wall, 36" east side man-door, 20A GFCI bench receptacles, and a dedicated 240V EV charger stub-out.
  • ANSI Z765-2021 GLA Separation: Heated above-grade living area is calculated distinctly from unheated garages, mechanical/utility rooms, and detached structures so MLS sheets and preliminary appraisals stay transparent.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is preliminary space-planning and CAD drafting software, not a licensed architectural or structural engineering firm. All templates, takeoff quantities, and exported sheets are for design planning, estimating, and contractor coordination. Verify all site dimensions, soil and structural load paths, header sizing, egress openings, and local building code amendments with a licensed professional and your local building department prior to construction.