4-Bedroom Modern Farmhouse Residence

2,240 sq ft split-bedroom 4-Bed / 2.5-Bath farmhouse with open great room, chef island & walk-in pantry

TPL-24 • PC-2026-124 Remodel & Whole Home 4 Bed / 2.5 Bath Ceiling 9'-0"
SHEET A-201 • ARCHITECTURAL FLOOR PLAN PREVIEW OVERALL 56'-0" x 40'-0"
4-Bedroom Modern Farmhouse Residence scaled architectural floor plan showing walls, door swings, glazing, and room dimensions

Room Schedule (12 Enclosed Zones)

INSET CLEAR INTERIOR DIMENSIONS
Room NameClear Interior SpanClear Area (sq ft)Floor FinishGLA Status
Mudroom & Laundry15'-3" x 7'-3"111 sq ftPorcelain TileHeated GLA
Great Room & Kitchen22'-8" x 38'-11"880 sq ftWhite Oak HardwoodHeated GLA
Powder Room4'-8" x 5'-3"24 sq ftPorcelain TileHeated GLA
Bedroom 211'-3" x 10'-3"116 sq ftCut-Pile CarpetHeated GLA
Shared Full Bath11'-3" x 6'-8"75 sq ftPorcelain TileHeated GLA
Bedroom 311'-3" x 10'-8"120 sq ftCut-Pile CarpetHeated GLA
Bedroom 4 / Flex Office16'-3" x 10'-3"167 sq ftWhite Oak HardwoodHeated GLA
Primary Bedroom15'-3" x 15'-3"233 sq ftCut-Pile CarpetHeated GLA
Primary Bath15'-3" x 8'-8"132 sq ftPorcelain TileHeated GLA
Primary Walk-In Closet8'-3" x 6'-8"55 sq ftCut-Pile CarpetHeated GLA
Walk-In Pantry6'-8" x 6'-8"44 sq ftWhite Oak HardwoodHeated GLA
Bedroom Hallway4'-8" x 22'-8"105 sq ftWhite Oak HardwoodHeated GLA

Doors & Cased Openings (14)

Opening TypeClear WidthQty
Single Hinged Door
80" head height, clear swing arc
3'-0" (36")2
Sliding Glass / Patio Door
Tempered safety glazing
6'-0" (72")1
Single Hinged Door
80" head height, clear swing arc
2'-10" (34")2
Single Hinged Door
80" head height, clear swing arc
2'-6" (30")3
Recessed Pocket Door
Zero swing-arc wall pocket
2'-6" (30")2
Cased Archway Opening
Trimmed pass-through (verify header)
4'-0" (48")1
Single Hinged Door
80" head height, clear swing arc
2'-8" (32")3

Windows & Egress Glazing (12)

Glazing TypeRough WidthQty
Standard Architectural Window
Double-pane insulated glazing
3'-0" (36")4
Standard Architectural Window
Double-pane insulated glazing
4'-0" (48")3
IRC R310 Egress Window
Min 5.7 sq ft net clear opening, <=44" sill
4'-0" (48")4
Standard Architectural Window
Double-pane insulated glazing
2'-6" (30")1

Kitchen, Bath & Architectural Fixtures (25)

MarkFixture / Cabinet DescriptionPlan FootprintQty
REF-3636" Refrigerator28" W x 36" D1
B3030" Base Cabinet24" W x 30" D1
SB3636" Sink Base24" W x 36" D1
DW-2424" Dishwasher24" W x 24" D1
RNG-3030" Range26" W x 30" D1
ISL-36x9636"x96" Chef Island36" W x 96" D1
DIN-7272" Farmhouse Table42" W x 72" D1
SOFA-8484" Great Room Sofa84" W x 36" D1
WD-54Side-by-Side Laundry54" W x 28" D1
WH-5050-Gal Water Heater24" W x 24" D1
PNT-48Pantry Shelving20" W x 48" D1
BED-K1Primary King Bed76" W x 80" D1
VAN-6060" Dual Primary Vanity60" W x 21" D1
SHW-4848"x36" Walk-In Shower48" W x 36" D1
TUB-6060" Freestanding Tub60" W x 30" D1
WC-1Primary WC20" W x 27" D1
WC-PPowder WC20" W x 27" D1
VAN-2424" Powder Vanity24" W x 18" D1
BED-Q2Bedroom 2 Queen Bed60" W x 80" D1
TUB-60B60" Shared Tub60" W x 30" D1
WC-2Hall WC20" W x 27" D1
VAN-4848" Hall Vanity48" W x 21" D1
BED-Q3Bedroom 3 Queen Bed60" W x 80" D1
DSK-60Flex Office Desk60" W x 30" D1
BED-Q4Bedroom 4 Queen Bed60" W x 80" D1

IRC / NKBA Space-Planning Notes & Scope Disclaimer

  • Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
  • NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is preliminary space-planning and CAD drafting software, not a licensed architectural or structural engineering firm. All templates, takeoff quantities, and exported sheets are for design planning, estimating, and contractor coordination. Verify all site dimensions, soil and structural load paths, header sizing, egress openings, and local building code amendments with a licensed professional and your local building department prior to construction.