24x18 Primary Suite Room Addition
432 sq ft primary bedroom bump-out with en-suite full bath, walk-in closet & house tie-in door
Room Schedule (3 Enclosed Zones)
| Room Name | Clear Interior Span | Clear Area (sq ft) | Floor Finish | GLA Status |
|---|---|---|---|---|
| Primary Bedroom | 13'-9" x 16'-11" | 233 sq ft | White Oak Hardwood | Heated GLA |
| En-Suite Full Bath | 8'-9" x 9'-9" | 86 sq ft | Porcelain Tile | Heated GLA |
| Walk-In Closet | 8'-9" x 6'-9" | 59 sq ft | White Oak Hardwood | Heated GLA |
Doors & Cased Openings (3)
| Opening Type | Clear Width | Qty |
|---|---|---|
Single Hinged Door 80" head height, clear swing arc | 3'-0" (36") | 1 |
Recessed Pocket Door Zero swing-arc wall pocket | 2'-6" (30") | 2 |
Windows & Egress Glazing (4)
| Glazing Type | Rough Width | Qty |
|---|---|---|
IRC R310 Egress Window Min 5.7 sq ft net clear opening, <=44" sill | 4'-0" (48") | 1 |
Standard Architectural Window Double-pane insulated glazing | 4'-0" (48") | 1 |
Standard Architectural Window Double-pane insulated glazing | 3'-0" (36") | 1 |
Standard Architectural Window Double-pane insulated glazing | 2'-6" (30") | 1 |
Kitchen, Bath & Architectural Fixtures (7)
| Mark | Fixture / Cabinet Description | Plan Footprint | Qty |
|---|---|---|---|
| BED-Q1 | Queen Bed | 60" W x 80" D | 1 |
| DRS-48 | 48" Dresser Credenza | 48" W x 20" D | 1 |
| SHW-48 | 48"x36" Walk-In Shower | 48" W x 36" D | 1 |
| WC-1 | En-Suite WC | 20" W x 27" D | 1 |
| VAN-48 | 48" Single Vanity | 48" W x 21" D | 1 |
| CLS-60A | 60" Wardrobe Shelving | 60" W x 20" D | 1 |
| CLS-60B | 60" Double-Hang Rod | 60" W x 20" D | 1 |
IRC / NKBA Space-Planning Notes & Scope Disclaimer
- Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
- NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is
preliminary space-planning and CAD drafting software, not a licensed architectural or
structural engineering firm. All templates, takeoff quantities, and exported sheets are for
design planning, estimating, and contractor coordination. Verify all site dimensions, soil
and structural load paths, header sizing, egress openings, and local building code
amendments with a licensed professional and your local building department prior to
construction.