Verify toilet alcove widths, bowl front clearances, vanity aisles, double-sink spacing,
walk-in shower dimensions, and door swing arcs against IRC P2705.1 / R307.1 code minimums
and NKBA comfort guidelines—with a live scaled 2D fixture plan and tile takeoff.
15" CL / 32" frontIRC min 15" CL / 21" front • NKBA 18" / 30"
Vanity Aisle & SinkPASS
3'-3" (39")Single sink: 18" to side wall
Floor Tile + 10% WasteESTIMATE
25 sq ft (22.2 net)Plus ~66 sq ft wet-wall surround (6' H)
Room & Fixture Inputs
IRC P2705.1
Standard US Bathroom Presets
5'-0"
8'-0"
Scaled 2D Bathroom Fixture & Clearance Plan
Dashed zones show toilet side alcove (30") and IRC 21" / NKBA 30" front clearance. All dimensions live in ft'-in".
SHEET B-101 • PLAN
LAYOUT ARCHETYPESingle Wet-Wall Standard
GROSS / NET FLOOR TILE AREA40 gross / 22.2 net sq ft
TILE ORDER (+10% WASTE)25 sq ft floor + 66 sq ft wall
IRC P2705.1 / R307.1 vs. NKBA Compliance Ledger
Every fixture clearance is evaluated simultaneously against International Residential Code
minimums and NKBA Bathroom Planning comfort recommendations.
6 RULES CHECKED
Clearance Rule & Code Ref
Actual
IRC Min
NKBA Rec
Status
Actionable Fix Hint
Toilet Side Centerline Clearance
IRC P2705.1 / R307.1
15" each side (30" alcove)
>= 15" (30" alcove)
>= 18" (36" alcove)
IRC OK · TIGHT
Meets IRC 15" centerline minimum; widen alcove to 36" (+6") for NKBA comfort.
Toilet Front Clear Space
IRC P2705.1 / R307.1
32" (2'-8")
>= 21"
>= 30"
PASS
Comfortable front legroom meeting NKBA 30" guideline.
Vanity Front Clear Aisle
IRC P2705.1 / NKBA
39" (3'-3")
>= 21"
>= 30"
PASS
Meets NKBA 30" standing and drawer-pull clearance.
Lavatory Centerline to Side Wall
IRC P2705.1 / NKBA
18" to nearest wall
>= 15"
>= 20"
IRC OK · TIGHT
Meets 15" IRC minimum; use a >= 40" vanity for 20" NKBA elbow clearance.
Entry Door Width & Swing Clearance
IRC R311 / NKBA
30" inswing
>= 24" & no collision
>= 32" & clear arc
IRC OK · TIGHT
Standard 30" bath door; widen to 32" for NKBA / accessible clear passage.
Wall-Run Fixture Fit
Plan Geometry
96" used / 96" wall
0" overlap
Clean fit inside walls
PASS
All fixtures fit cleanly inside room dimensions without wall-run overlap.
Draft This Bathroom Layout in Exact 2D & 3D CAD
Launch the Primary Bath template in PlanCaliber's browser CAD studio to adjust walls,
plumbing walls, GFCI receptacles, and 3D sightlines. Export when ready with a $9 Clean Print & Share Pass (2-sheet 1/4"=1'-0" PDF A-101 +
M-101, 2400px PNG, SVG, shareable 2D/3D link) or $19 Full CAD Pack (5-sheet
PDF, layered AutoCAD R12 .DXF, 3D .OBJ, Takeoff .CSV).
This calculator is a preliminary space-planning reference based on model IRC P2705.1 / R307.1
clearances and NKBA Bathroom Planning Guidelines. Always verify state and municipal code
amendments, rough-in plumbing centerlines, structural framing, and accessibility requirements
with a licensed plumber, contractor, or local Authority Having Jurisdiction (AHJ) before
framing or rough-in.
What is the minimum IRC toilet clearance on the sides and in front?
IRC P2705.1 / R307.1 requires at least 15" from the
toilet centerline to any side wall, vanity, or partition (30" total
alcove width) and at least 21" clear floor space in front of the
front rim of the bowl. NKBA recommends 18" per side
(36" alcove) and 30" in front.
What is the minimum size for a walk-in shower under IRC R307.1?
IRC R307.1 / P2708.1 sets a minimum finished interior shower floor area
of 900 sq in capable of encompassing a 30" circle
(30"×30" minimum). For comfortable daily showering without elbow
bumping, NKBA recommends at least 36"×36" (1,296 sq in) or a 36"×60" tub-to-shower conversion.
How wide does a double-sink bathroom vanity need to be?
Each lavatory centerline needs at least 15" to the adjacent side wall
and 30" center-to-center between basins under IRC P2705.1—meaning 60" is the absolute code minimum for two sinks. For NKBA's 36" center-to-center spacing, specify at least a 66" or 72" double vanity.
When should a bathroom use an outswing or pocket door?
In compact 3'×6' powder rooms or narrow guest baths where a 28"–30" inswing door arc collides with the toilet or vanity
clearance zone, switching to an outswing or pocket door recovers 6–9 sq ft of usable floor clearance and prevents fixture collisions.