Primary Bath + Walk-In Suite

72" double vanity, freestanding 60" tub, 48"x36" shower & walk-in closet

TPL-09 • PC-2026-109 Kitchen & Bath Primary Bath + WIC Ceiling 9'-0"
SHEET A-201 • ARCHITECTURAL FLOOR PLAN PREVIEW OVERALL 18'-0" x 14'-0"
Primary Bath + Walk-In Suite scaled architectural floor plan showing walls, door swings, glazing, and room dimensions

Room Schedule (3 Enclosed Zones)

INSET CLEAR INTERIOR DIMENSIONS
Room NameClear Interior SpanClear Area (sq ft)Floor FinishGLA Status
Primary Bath11'-3" x 12'-11"146 sq ftPorcelain TileHeated GLA
Water Closet5'-3" x 4'-9"25 sq ftPorcelain TileHeated GLA
Walk-In Closet5'-3" x 7'-9"41 sq ftWhite Oak HardwoodHeated GLA

Doors & Cased Openings (3)

Opening TypeClear WidthQty
Single Hinged Door
80" head height, clear swing arc
2'-8" (32")1
Recessed Pocket Door
Zero swing-arc wall pocket
2'-4" (28")1
Recessed Pocket Door
Zero swing-arc wall pocket
2'-6" (30")1

Windows & Egress Glazing (2)

Glazing TypeRough WidthQty
Standard Architectural Window
Double-pane insulated glazing
3'-6" (42")1
Standard Architectural Window
Double-pane insulated glazing
2'-0" (24")1

Kitchen, Bath & Architectural Fixtures (5)

MarkFixture / Cabinet DescriptionPlan FootprintQty
TUB-6060" Freestanding Soaking Tub60" W x 32" D1
SHW-4848"x36" Curbless Glass Shower48" W x 36" D1
VAN-7272" Dual-Sink Quartz Vanity22" W x 72" D1
WC-1Wall-Hung Smart WC20" W x 27" D1
CLS-60Custom Closet Wardrobe Tower18" W x 60" D1

IRC / NKBA Space-Planning Notes & Scope Disclaimer

  • Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
  • NKBA Kitchen & Bath Planning Clearances: Work aisles around islands and opposing base cabinets target 42" minimum for single-cook layouts (48" recommended for multi-cook zones), 21" clear in front of dishwashers/ranges, and 30" minimum fixture width at water closets and vanities.
  • NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is preliminary space-planning and CAD drafting software, not a licensed architectural or structural engineering firm. All templates, takeoff quantities, and exported sheets are for design planning, estimating, and contractor coordination. Verify all site dimensions, soil and structural load paths, header sizing, egress openings, and local building code amendments with a licensed professional and your local building department prior to construction.