Chef's Kitchen + Dining Remodel
Load-bearing wall opening with 36"x84" island, pantry & 44" NKBA work aisles
Room Schedule (3 Enclosed Zones)
| Room Name | Clear Interior Span | Clear Area (sq ft) | Floor Finish | GLA Status |
|---|---|---|---|---|
| Chef's Kitchen | 15'-7" x 16'-11" | 264 sq ft | White Oak Hardwood | Heated GLA |
| Walk-In Pantry | 6'-11" x 4'-9" | 33 sq ft | White Oak Hardwood | Heated GLA |
| Dining Room | 6'-11" x 11'-9" | 82 sq ft | White Oak Hardwood | Heated GLA |
Doors & Cased Openings (4)
| Opening Type | Clear Width | Qty |
|---|---|---|
Recessed Pocket Door Zero swing-arc wall pocket | 2'-4" (28") | 1 |
Cased Archway Opening Trimmed pass-through (verify header) | 9'-0" (108") | 1 |
Single Hinged Door 80" head height, clear swing arc | 3'-0" (36") | 1 |
Sliding Glass / Patio Door Tempered safety glazing | 5'-0" (60") | 1 |
Windows & Egress Glazing (2)
| Glazing Type | Rough Width | Qty |
|---|---|---|
Standard Architectural Window Double-pane insulated glazing | 4'-0" (48") | 2 |
Kitchen, Bath & Architectural Fixtures (11)
| Mark | Fixture / Cabinet Description | Plan Footprint | Qty |
|---|---|---|---|
| REF-36 | 36" Pro Refrigerator | 36" W x 28" D | 1 |
| B24 | 24" Prep Base Cabinet | 24" W x 24" D | 1 |
| SB36 | 36" Apron Sink Base | 36" W x 24" D | 1 |
| DW24 | 24" Dishwasher | 24" W x 24" D | 1 |
| RNG-30 | 30" Pro Gas/Induction Range | 30" W x 25" D | 1 |
| B24 | 24" Spice/Drawer Base | 24" W x 24" D | 1 |
| W3036 | 30" Upper Wall Cabinet | 24" W x 12" D | 1 |
| W2436 | 24" Upper Wall Cabinet | 24" W x 12" D | 1 |
| PNT-48 | Pantry Shelving Unit | 48" W x 18" D | 1 |
| ISL-36x84 | 36"x84" Waterfall Quartz Island | 84" W x 36" D | 1 |
| TBL-72 | 72" Solid Oak Dining Table | 38" W x 72" D | 1 |
IRC / NKBA Space-Planning Notes & Scope Disclaimer
- Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
- NKBA Kitchen & Bath Planning Clearances: Work aisles around islands and opposing base cabinets target 42" minimum for single-cook layouts (48" recommended for multi-cook zones), 21" clear in front of dishwashers/ranges, and 30" minimum fixture width at water closets and vanities.
- NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is
preliminary space-planning and CAD drafting software, not a licensed architectural or
structural engineering firm. All templates, takeoff quantities, and exported sheets are for
design planning, estimating, and contractor coordination. Verify all site dimensions, soil
and structural load paths, header sizing, egress openings, and local building code
amendments with a licensed professional and your local building department prior to
construction.