NEC 210.52 Electrical Outlet Placement Calculator

Size duplex receptacle counts, GFCI and AFCI protection requirements, and 15A or 20A branch circuits across living rooms, bedrooms, kitchen countertops, bathrooms, garages, and hallways with a live scaled 2D electrical schematic.

TOTAL RECEPTACLES 5 5 wall + 0 dedicated
PROTECTION REQUIRED AFCI NEC 2023 210.52(A) & 210.12
BRANCH CIRCUITS 1 1 x 15A AFCI general branch circuit (max 8 outlets/circuit)
MAX SPACING RULE Max 6 ft from door/break, 12 ft O.C. max 14'-0" x 12'-0" (46 LF usable)

Room Geometry & Circuit Parameters

NEC 2023
General Branch Circuit Rating

Kitchens, bathrooms, and garages require dedicated 20A branch circuits regardless of general lighting circuit sizing.

Receptacle & Load Breakdown

Gross Perimeter
52 LF
Usable Wall Space
46 LF
General / Workbench Wall Outlets
5
Counter / Basin / Bay Outlets
0
Total Duplex Receptacles
5

Live 2D Electrical Schematic (Sheet E-101 Preview)

LAYER E-POWR
14'-0"12'-0"LIVING / BEDROOM5 DUPLEX · AFCI · 1 CKTR1R2R3R4R5DUPLEX (AFCI) · NEC 2023 210.52(A) & 210.12SHEET E-101
Auto-Generate Sheet E-101 & AutoCAD Layer E-POWR

Drafting in 2D/3D and saving a watermarked proof PNG are free. Unlock PlanCaliber's $19 Full CAD Pack to export Sheet E-101 (Electrical & Lighting Plan) as a true-scale vector PDF plus an AutoCAD R12 .DXF with layer E-POWR (ACI Yellow 2).

Open Room in 2D/3D Studio (Auto E-101 Electrical Plan)

NEC 2023 Section 210.52 Quick Reference

Room / SpaceNEC CitationMax Spacing RuleProtectionBranch Circuit Baseline
Living / Bedroom / Den210.52(A), 210.12Max 6 ft from doorway/break; 12 ft O.C.; walls >= 2 ftAFCI15A or 20A general branch (8 to 10 outlets/ckt)
Kitchen & Countertops210.52(C), 210.8(A)(6)Max 24" from counter edge; 48" O.C. along countertopGFCI + AFCIMin 2 dedicated 20A Small-Appliance Circuits
Bathroom & Vanity210.52(D), 210.11(C)(3)Min 1 outlet within 36" of outside edge of each basinGFCIMin 1 dedicated 20A bathroom branch circuit
Garage / Workshop210.52(G)(1), 210.11(C)(4)Min 1 outlet per vehicle bay + 6 ft O.C. workbench wallGFCIMin 1 dedicated 20A garage branch circuit
Hallway (>= 10 ft)210.52(H), 210.12Min 1 outlet for hallways >= 10 ft (1 per 15 ft typical)AFCIShared 15A or 20A general lighting/receptacle circuit

Electrical Outlet Spacing FAQ

What is the NEC 6-foot and 12-foot wall outlet spacing rule?

Under NEC 210.52(A), no point measured horizontally along the floor line of any usable wall space in living rooms, bedrooms, dens, or dining rooms may be more than 6 feet from a receptacle outlet. That results in a maximum spacing of 12 feet between wall outlets, and any continuous wall segment 2 feet or wider requires at least one receptacle.

How far apart must kitchen countertop outlets be spaced under NEC 210.52(C)?

Kitchen countertops require receptacles so no point along the wall line is more than 24 inches from an outlet, meaning countertop outlets are spaced no more than 48 inches (4 feet) apart. Kitchens also require at least two dedicated 20-amp Small-Appliance Branch Circuits with GFCI and AFCI protection.

Do bathroom and garage receptacles require dedicated 20-amp GFCI circuits?

Yes. NEC 210.52(D) and 210.11(C)(3) require at least one GFCI-protected receptacle within 36 inches of the outside edge of each bathroom basin on a dedicated 20-amp branch circuit. NEC 210.52(G)(1) and 210.11(C)(4) require at least one GFCI receptacle per vehicle bay in attached garages on a dedicated 20-amp garage branch circuit.

When does a residential hallway require a wall receptacle?

Per NEC 210.52(H), any hallway 10 feet or longer measured along the centerline must have at least one AFCI-protected receptacle outlet. Longer corridors typically place one outlet per 15 feet for practical vacuum and utility cord reach.

Preliminary Space-Planning Notice: This calculator provides preliminary electrical outlet quantity and spacing estimates based on NEC 2023 Section 210.52 general residential guidelines. Local amendments, adopted NEC edition year, kitchen island/peninsula rules, and load calculations vary by jurisdiction. Always verify final electrical layouts and panel capacity with your local Authority Having Jurisdiction (AHJ) and a licensed electrician before rough-in or installation.