Paver Patio, Compacted Gravel Base & Sand Calculator

Size US interlocking concrete pavers across 4"x8", 6"x9", 12"x12", and 16"x16" formats, apply Running Bond, Herringbone, or 45-degree Diagonal cut waste, compute 3/4" minus crushed road base with an ICPI 6" over-excavation collar and +25% compaction fluff, and count ASTM C33 bedding sand, polymeric joint sand, 8' edge restraints, and 10" steel spikes.

TOTAL PAVERS (+7% CUTS) 548 pavers 6"x9" Cobble · 512 net (~2.06 pallets)
CRUSHED STONE BASE (+25%) 3.41 cu yd 4.6 tons · 4" deep (+6" collar)
BEDDING & POLYMERIC SAND 36 C33 / 3 poly 0.65 cu yd (1" bed) · 50-lb bags
EDGING, SPIKES & DIG DEPTH 7.38" dig 5x 8' sticks · 40 spikes · 3" fall

Patio Footprint & ICPI Sub-Base Specs

ICPI / ASTM C33
US Paver Format & Joint Density
Laying Bond Pattern (Auto-Sets Cut Waste)
Compacted Gravel Base & Bedding Sand Depth
Net Patio / ICPI Over-Dig Area 192 sf / 221 sf
Pavers (6"x9" Cobble, +7%) 548 units (~2.06 pallets)
3/4" Road Base (4" + 25% fluff) 3.41 cu yd (4.6 tons)
ASTM C33 Bedding Sand (1" + 10%) 0.65 cu yd (0.88 tons / 36 bags)
Polymeric Joint Sand (75 sf/bag) 3 x 50-lb bags
Edge Restraint & 10" Spikes (12" OC) 5 x 8' sticks + 40 spikes
Total Dig Depth / 1/4"/ft Drainage Fall 7.38" deep / 3" drop

Sheet L-101: Paver Bond & ICPI Sub-Base Section

RUNNING BOND
SHEET L-101 · PAVER BOND & ICPI SUB-BASE SECTIONRUNNING BOND · 16'x12' (192 SF)PLAN BOND: RUNNING BOND (6"X9" COBBLE · +7% CUTS)EDGING: 3 OPEN SIDES (40 LF)1/4"/FT DRAINAGE SLOPE AWAY FROM HOUSE (3" TOTAL FALL)COMPACTED NATIVE SUBGRADE SOIL (ADD GEOTEXTILE OVER CLAY)4" COMPACTED 3/4" GRAVEL BASE (+25% FLUFF · 2" LIFTS)1" ASTM C33 WASHED BEDDING SAND2-3/8" PAVERS (60mm) + POLYMERIC SAND JOINTSEDGE +10" SPIKE6" OVER-DIGCOLLARTOTAL DIG7.38"ORDER: 548 PAVERS · 4.6 TONS BASE · 36 BAGS SAND · 3 POLY BAGS

ICPI Sub-Base, Drainage & Call-811 Advisories

  • Grade sub-base at 1/4" per foot away from house foundations (3" total fall across 12'-0" patio width) to shed rainwater.
  • Over-excavate 6" past every exposed edge (17' x 13' = 221 sq ft dig) and compact 3/4" minus road base in 2" lifts with a vibratory plate compactor (+25% loose fluff included).
  • Call 811 Before You Dig at least 3 business days before excavating 7.38" deep to mark underground utility lines.
  • Screed ASTM C33 washed concrete sand to a uniform 1" depth using 1" OD conduit pipes; never use fine mason sand or stone dust for the bedding layer.
Draft Full Backyard Patio & Outdoor Living Plans in 2D/3D Studio

Lay out your patio, pool house, grill island, and yard setbacks free ($0) with watermarked proof PNGs. Export clean unwatermarked Vector PDF from $9 one-time, or full 5-sheet Vector PDF + AutoCAD R12 .DXF + Material Takeoff .CSV for $19.

US Paver Formats, ICPI Sub-Base & Polymeric Sand Yield Reference

Paver Format / Base LayerUnit Area / FactorPolymeric / Weight YieldICPI Depth RuleRecommended US Application
4" x 8" Standard Brick Paver0.222 sf (4.5 / sf)60 sq ft / 50-lb bag4" patio / 6" heavyWalkways, 90-degree herringbone fire-pit patios, and soldier borders
6" x 9" Holland / Cobble Paver0.375 sf (2.67 / sf)75 sq ft / 50-lb bag4" patio / 6" clayStandard US backyard dining patios, grill stations, and running-bond decks
12" x 12" Patio Slab1.000 sf (1.0 / sf)100 sq ft / 50-lb bag6" compacted baseHot tub pads, outdoor kitchen bases, and clean modular grids
16" x 16" Large Format Slab1.778 sf (0.56 / sf)120 sq ft / 50-lb bag6" compacted baseModern courtyards, poolside seating zones, and low-joint terraces
3/4" Minus Crushed Road Base+25% loose fluff1.35 tons / loose cu ydCompact in 2" liftsICPI structural sub-base extended 6" past every exposed paver edge
ASTM C33 Washed Concrete Sand1" screeded bed0.5 cu ft / 50-lb bagNever exceed 1.5"Leveling bedding layer screeded on 1" OD conduit; avoid fine play sand

Paver Patio, Gravel Base & Polymeric Sand FAQ

Why does the crushed gravel base need a +25% compaction factor and a 6" over-dig collar?

Loose 3/4" minus crushed stone (Class 2 road base) compresses by roughly 20% to 25% when compacted in 2-inch lifts with a vibratory plate compactor. Ordering 1.25x the compacted volume prevents coming up short on delivery day. Extending the excavated base 6 inches past every exposed patio edge (an ICPI standard) gives the edge restraint and 10-inch steel spikes solid compacted stone to anchor into so outer pavers cannot tip or spread.

How deep should I excavate for a US backyard paver patio?

Add your compacted gravel base depth (4 inches for standard pedestrian patios, 6 inches for fire pits, hot tubs, outdoor kitchens, or freeze-thaw clay soils, and 8 inches for driveway aprons) plus 1 inch of screeded washed bedding sand plus 2-3/8 inches (60mm) for the concrete paver thickness. A standard 4-inch base patio requires 7-3/8 inches (7.38") total excavation below finished grade.

What kind of sand goes under pavers vs. between the joints?

Use coarse, angular washed concrete sand (ASTM C33) screeded to a uniform 1-inch depth for the bedding layer. Never use fine play sand, mason sand, or stone dust under pavers, and never exceed 1.5 inches of bedding sand or the patio will settle unevenly. Once the pavers are laid and edge restraints are spiked down, sweep dry polymeric joint sand into the joints, compact the pavers, blow off the surface, and mist lightly to lock the joints.

How much cut waste should I add for Running Bond vs. Herringbone vs. 45-Degree Diagonal?

Running bond typically requires 7% extra pavers for straight perimeter cuts and breakage. A 90-degree herringbone weave requires about 12% extra due to frequent edge cuts around borders, while a 45-degree diagonal pattern requires roughly 15% extra because every straight edge produces angled triangular offcuts.

What drainage slope should a paver patio have away from the house?

ICPI guidelines recommend a minimum slope of 1/4 inch per foot (about 2% grade) away from house foundations and structures so rainwater sheds cleanly off the patio. On a 12-foot-wide patio, the outer edge should sit 3 inches lower than the ledger edge against the house.

Preliminary Hardscape Estimating & Call-811 Field-Verification Notice: This calculator provides preliminary hardscape planning and material takeoffs based on ICPI pedestrian and light-duty guidelines. Actual excavation depth, aggregate compaction, geotextile fabric needs, freeze-thaw frost heave protection, and stormwater drainage vary by native soil bearing capacity and local municipal codes. Always call 811 Before You Dig to locate underground utilities and verify site drainage, property setbacks, and HOA rules before excavating or ordering bulk stone and pavers.