12x16 Mudroom, Laundry & Drop-Zone Suite

192 sq ft remodel with side-by-side washer/dryer (6" rear vent clearance), 24" utility sink, 18" locker bench & pocket door

TPL-30 • PC-2026-130 Kitchen & Bath Laundry & Mudroom Ceiling 9'-0"
SHEET A-201 • ARCHITECTURAL FLOOR PLAN PREVIEW OVERALL 16'-0" x 12'-0"
12x16 Mudroom, Laundry & Drop-Zone Suite scaled architectural floor plan showing walls, door swings, glazing, and room dimensions

Room Schedule (2 Enclosed Zones)

INSET CLEAR INTERIOR DIMENSIONS
Room NameClear Interior SpanClear Area (sq ft)Floor FinishGLA Status
Laundry & Mudroom14'-11" x 10'-11"150 sq ftPorcelain TileHeated GLA
Coat Closet3'-3" x 3'-3"11 sq ftPorcelain TileHeated GLA

Doors & Cased Openings (3)

Opening TypeClear WidthQty
Single Hinged Door
80" head height, clear swing arc
3'-0" (36")1
Recessed Pocket Door
Zero swing-arc wall pocket
2'-8" (32")1
Closet Bifold Door
Wardrobe / laundry access
2'-6" (30")1

Windows & Egress Glazing (2)

Glazing TypeRough WidthQty
Standard Architectural Window
Double-pane insulated glazing
3'-0" (36")1
Standard Architectural Window
Double-pane insulated glazing
2'-6" (30")1

Kitchen, Bath & Architectural Fixtures (5)

MarkFixture / Cabinet DescriptionPlan FootprintQty
WD-56Washer & Dryer (6" Vent)56" W x 28" D1
SB2424" Utility Sink24" W x 24" D1
B2424" Folding Counter24" W x 24" D1
LCK-48A48" Mudroom Locker Bench48" W x 18" D1
LCK-48B48" Boot & Coat Bench48" W x 18" D1

IRC / NKBA Space-Planning Notes & Scope Disclaimer

  • Wall Assembly & Framing Basis: Exterior walls are modeled at 6-1/2" overall thickness (2x6 nominal framing at 16" OC plus sheathing/gypsum) and interior partitions at 4-1/2" (2x4 nominal framing plus 1/2" gypsum each side) with a 9'-0" ceiling plate height.
  • IRC M1502 Dryer Vent & NKBA Laundry Clearances: Side-by-side 56" washer/dryer pair is set 6" off the north exterior wall for rigid dryer duct clearance alongside a 24" utility sink, 24" folding counter, 18" south mudroom locker bench (leaving a >48" walkway), and a 32" pocket door to prevent door-swing conflict.
  • NKBA Kitchen & Bath Planning Clearances: Work aisles around islands and opposing base cabinets target 42" minimum for single-cook layouts (48" recommended for multi-cook zones), 21" clear in front of dishwashers/ranges, and 30" minimum fixture width at water closets and vanities.
  • NEC 210.8 & 210.52 Preliminary Electrical Layout: Countertop receptacles, bath vanities, laundry alcoves, and exterior/garage zones require GFCI protection; hallway and sleeping zones require interconnected smoke/CO alarms per local residential code.
Preliminary Space-Planning & CAD Drafting Notice: PlanCaliber is preliminary space-planning and CAD drafting software, not a licensed architectural or structural engineering firm. All templates, takeoff quantities, and exported sheets are for design planning, estimating, and contractor coordination. Verify all site dimensions, soil and structural load paths, header sizing, egress openings, and local building code amendments with a licensed professional and your local building department prior to construction.